EVALUATION OF ADOPTION OF LED LIGHTING TECHNOLOGY IN MALAYSIA
Version 2 2022-07-06, 05:26Version 2 2022-07-06, 05:26
Version 1 2017-09-26, 23:23Version 1 2017-09-26, 23:23
thesis
posted on 2017-09-26, 23:23authored byHasti Khorasanizadeh
Electrical
energy consumption in Malaysia is rapidly increasing with illumination being
the second largest contributor to this increment. Light Emitting Diode (LED)
could be a viable option to reduce the illumination based energy consumption.
LEDs are energy efficient and easier to recycle compared to traditional
lighting sources such as incandescent and fluorescent lamps. They also have
longer life time and lower failure rate. In this thesis, the feasibility of
replacing the traditional light sources with LEDs is evaluated in the Malaysian
context.
In this thesis, Unified Theory of Acceptance and Use of
Technology (UTAUT) is modified to understand the adoption of LED-lighting in
Malaysia. Performance expectancy, effort expectancy, facilitating condition,
social influence and behavior intention are the basic factors in UTAUT.
However, in this study, four other factors were added to investigate environmental,
social and cultural effects. These factors are: past buying behavior,
postmodernist values, media exposure and environmental values. Results show
that, for rapid adoption of LEDs in Malaysia, technology and environmental
awareness and social engagement should be enhanced simultaneously. On a global
scale, replacement of traditional light sources with LEDs will result in
significant benefits including considerable energy savings, substantial
reduction in CO2 emissions, significant drop in the emission of pollutants such
as SO2 (source of acid rain), mercury (Hg), uranium (U) and increase in
financial savings. Based on the calculations in this study, it was found that,
if 62% incandescent Lamps are replaced with LEDs, the emission
will drop to 0.145 Mtons by 2020 in residential buildings. This corresponds to
a CO2 emission reduction of 10.7 %. The LED adoption can be further encouraged
through government subsidies.
Study of beta activity of brain electroencephalography signal
(EEG) under different light sources shows that the amount of attention under
LED is higher compared to other sources with the same correlated color
temperature (CCT). Although the participants in this study prefer fluorescent
light in 3800 K in terms of pleasantness and visual comfort, they claim that
light from LED in 4150 K is more natural. This study recommends the wide
adoption of LED lighting in Malaysia through education. Activity theory is
suggested as the basis for the development of the educational model for
increasing the adoption of LEDs among public.